Determination of Solid's not Fat in Milk
At first Lactometer reading is taken at 21°C (For Zeal
Lactometer) at 27°C (For BIS lactometer) .
Then the SNF is calculated using the
formula.
%SNF
= CLR/4 + 0.21F + 0.36 (For Zeal Lactometer)
% SNF = ( CLR+ % Fat) / 4 + 0.44 (For BIS Lactometer)
For cow milk,
Lactometer reading is taken at 21OC. The SNF is calculated using
the formula.
%SNF
= CLR/4 + 0.2F + 0.14
Note:- CLR means Corrected Lactometer Reading
F = % of Fat in milk
"Chandan Pathak is Graduate in Engineering with Core B.tech in Dairy Technology.He is well known personality in Dairy Industry with many years of professional services with greatest Industry Brands in India e.g Amul, GSK-India, Ananda and several more. He is a also passionate writer which help many professional's, students to get help regarding career and support for growth for dairy development along with full technical support for enterpreneur's all over the world."